600A 1500Vdc High Voltage DC Relay Contactors

  • Max. Switching Voltage: 1500VDC
  • Rated Current: 600A
  • Main Contact Type: SPST-NO
  • Auxiliary Contact: Optional
  • Auxiliary Contact Type: SPST-NO
  • Coil Rated Voltage : 12VDC/24VDC/48VDC
  • Ambient Operation Temperature: -40°C~+85°C
  • Ambient Operation Humidity: 5%~85%RH
  • Approvals/Standard:
    • REACH
    • RoHS
    • UL 60947-4
    • CCC/CE/CB/S Mark
, , , , , ,

Description

MAIN CONTACT DATA
Max.Swilching Voltage 1500VDC Rated Current 600A
Contact Arrangement SPST-NO Contact Voltage Drop ≤0.12V(at600A)
Limiting Short-time Current 700A:10min:1000A:60s:1600A:10s;3000A:1s
Electrical Life (Resistive Load) 450V Model 800V Model 1000V Model 1500V Model
600A 450VDC 2000(ops),
Only Breaking
600A
800VDC 1500(ops),
Only Breaking
600A 1000VDC 1000(ops),
Only Breaking
600A 1500VDC 500(0ps),Only Breaking
400A 1500VDC 1000(ops),Cnly Breaking
Max.Breaking Current
(Resistive Load)
2000A 1000VDC 1(ops);1000A 1500VDC 1(0ps)
Overload Breaking (Resistive Load) 1000A 900VDC 100(ops)
Short Circuit Current Withstanding 8000A(5ms) No Smoke or Fire
CHARACTERISTIC DATA
Dielectria
Strength
Between Main Contacts
and Coil (Initial)
≥5000VAC(1min) Insulation
Resistance
Between Main Contacts
and Coll (Initial)
≥1000MQ(1500VDC)
Between Open Main
Contacts (Initial)
≥5000VAC(1min) Between Open Main
Contacts (Initial)
≥1000MQ(1500VDC)
Shock
Resistance
Functional 20g Half-Sine Wave 11ms Vibration
Resistance
Functional 5.79g (10-2000Hz,Random)
Destructive 50g Half-Sine Wave 6ms
Operate Time Max:50ms Mechanical Life 2*10^5 (ops)
Release Time Max:30ms Weight Approx 1300g
COIL DATA
Rated Voltage 12VDC 24VDC 48VDC
Pick-up Voltage ≤9VDC ≤18VDC ≤36VDC
Drop-out Voltage ≥1.2VDC ≥2.4VDC ≥4.8VDC
Rated Operating Power Approx60W(Start);
5.4W(Hold)
Approx60W(Start);
5.4W(Holo)
Approx60W(Start);
5.4W(Hold)
Max. Allowable Voltage 16VDC 32VDC 64VDC

 

MAIN CONTACT DATA
Max.Switching Voltage 1500VDC Rated Current 600A
Contact Arrangement SPST-NO Contact Voltage Drop ≤0.12V(at600A)
Limiting Short-time Current 700A:10min;1000A:60s;1600A:10s;3000A:1s
Electrical Life (Resistive Load) 450V Model 800V Model 1000V Model 1500V Model
600A 450VDC 2000 ops, Only Breaking 600A 800VDC 1500 ops, Only Breaking 600A 1000VDC 1000 ops, Only Breaking 600A 1500VDC 500 ops, Only Breaking; 400A 1500VDC 1000 ops, Only Breaking
Max. Breaking Current (Resistive Load) 2000A 1000VDC 1 ops; 1000A 1500VDC 1 ops
Overload Breaking (Resistive Load) 1000A 900VDC 100 ops
Short Circuit Current Withstanding 8000A(5ms) No Smoke or Fire
CHARACTERISTIC DATA
Dielectric Strength Between Main Contacts and Coil (Initial) ≥5000VAC(1min) Insulation Resistance Between Main Contacts and Coil (Initial) ≥1000MD(1500VDC)
Between Open Main Contacts (Initial) ≥5000VAC(1min) Between Open Main Contacts (Initial) ≥1000MD(1500VDC)
Shock Resistance Functional 20g Half-Sine Wave 11ms Vibration Resistance Functional 5.79g (10~2000Hz, Random)
Destructive 50g Hall-Sine Wave 6ms
Operate Time Max:50ms Mechanical Life 2*10^5 ops
Release Time Max:30ms Weight Approx 1300g
COIL DATA
Rated Voltage 12VDC 24VDC 48VDC
Pick-up Voltage ≤9VDC ≤18VDC ≤36VDC
Drop-out Voltage ≥1.2VDC ≥2.4VDC 24.8VDC
Rated Operating Power Approx 60W (Start); 5.4W (Hold) Approx 60W (Start); 5.4W (Hold) Approx 60W (Start); 5.4W (Hold)
Max. Allowable Voltage 16VDC 32VDC 64VDC

 

MAIN CONTACT DATA
Max.Switching Voltage 1500VDC Rated Current 600A
Contact Arrangement SPST-NO Contact Voltage Drop ≤0.12V(at600A)
Limiting Short-time Current 700A:10min;1000A:60s;1600A:10s;3000A:1s
Electrical Life (Resistive Load) 450V Model 800V Model 1000V Model 1500V Model
600A 450VDC 2000 ops, Only Breaking 600A 800VDC 1500 ops, Only Breaking 600A 1000VDC 1000 ops, Only Breaking 600A 1500VDC 500 ops, Only Breaking; 400A 1500VDC 1000 ops, Only Breaking
Max. Breaking Current (Resistive Load) 2000A 1000VDC 1 ops; 1000A 1500VDC 1 ops
Overload Breaking (Resistive Load) 1000A 900VDC 100 ops
Short Circuit Current Withstanding 8000A(5ms) No Smoke or Fire
CHARACTERISTIC DATA
Dielectric Strength Between Main Contacts and Coil (Initial) ≥5000VAC(1min) Insulation Resistance Between Main Contacts and Coil (Initial) ≥1000MO(1500VDC)
Between Open Main Contacts (Initial) ≥5000VAC(1min) Between Open Main Contacts (Initial) ≥1000MO(1500VDC)
Between Main Contacts and Auxiliary Contact (Initial) ≥5000VAC(1min) Between Main Contacts and Auxiliary Contact (Initial) ≥1000MO(1500VDC)
Shock Resistance Functional 20g Half-Sine Wave 11ms Vibration Resistance Functional 5.79g(10-2000Hz, Random)
Destructive 50g Half-Sine Wave 6ms
Operate Time Max:50ms Mechanical Life 2*10^5 ops
Release Time Max:30ms Weight Approx 1300g
COIL DATA
Rated Voltage 12VDC 24VDC 48VDC
Pick-up Voltage ≤9VDC ≤18VDC ≤36VDC
Drop-out Voltage ≥1.2VDC ≥2.4VDC ≥4.8VDC
Rated Operating Power Approx 60W (Start); 5.4W (Hold) Approx 60W (Start); 5.4W (Hold) Approx 60W (Start); 5.4W (Hold)
Max.Allowable Voltage 16VDC 32VDC 64VDC
AUXILIARY CONTACT DATA
Auxiliary Contact Arrangement SPST-NO Auxiliary Contact Range 100mA/8VDC~2A/30VDC
Auxiliary Contact Resistance ≤200mΩ (at 100mA)

 

MAIN CONTACT DATA
Max.Switching Voltage 1500VDC Rated Current 600A
Contact Arrangement SPST-NO Contact Voltage Drop ≤0.12V(at600A)
Limiting Short-time Current 700A:10min;1000A:60s;1600A:10s;3000A:1s
Electrical Life (Resistive Load) 450V Model 800V Model 1000V Model 1500V Model
600A 450VDC 2000 ops, Only Breaking 600A 800VDC 1500 ops, Only Breaking 600A 1000VDC 1000 ops, Only Breaking 600A 1500VDC 500 ops, Only Breaking; 400A 1500VDC 1000 ops, Only Breaking
Max. Breaking Current (Resistive Load) 2000A 1000VDC 1 ops; 1000A 1500VDC 1 ops
Overload Breaking (Resistive Load) 1000A 900VDC 100 ops
Short Circuit Current Withstanding 8000A(5ms) No Smoke or Fire
CHARACTERISTIC DATA
Dielectric Strength Between Main Contacts and Coil (Initial) ≥5000VAC(1min) Insulation Resistance Between Main Contacts and Coil (Initial) ≥1000MO(1500VDC)
Between Open Main Contacts (Initial) ≥5000VAC(1min) Between Open Main Contacts (Initial) ≥1000MO(1500VDC)
Between Main Contacts and Auxiliary Contact (Initial) ≥5000VAC(1min) Between Main Contacts and Auxiliary Contact (Initial) ≥1000MO(1500VDC)
Shock Resistance Functional 20g Half-Sine Wave 11ms Vibration Resistance Functional 5.79g(10-2000Hz, Random)
Destructive 50g Half-Sine Wave 6ms
Operate Time Max:50ms Mechanical Life 2*10^5 ops
Release Time Max:30ms Weight Approx 1300g
COIL DATA
Rated Voltage 12VDC 24VDC 48VDC
Pick-up Voltage ≤9VDC ≤18VDC ≤36VDC
Drop-out Voltage ≥1.2VDC ≥2.4VDC ≥4.8VDC
Rated Operating Power Approx 60W (Start); 5.4W (Hold) Approx 60W (Start); 5.4W (Hold) Approx 60W (Start); 5.4W (Hold)
Max.Allowable Voltage 16VDC 32VDC 64VDC
AUXILIARY CONTACT DATA
Auxiliary Contact Arrangement SPST-NO Auxiliary Contact Range 100mA/8VDC~2A/30VDC
Auxiliary Contact Resistance ≤200mΩ (at 100mA)

 

Applications

  • Electric vehicles
  • Rail transit
  • Charging system
  • Energy storage system
  • Photovoltaic system
  • Aviation
  • Military

Dimensions (mm)

HCF600-Dimension-1

HCF600-Dimension-2

HCF600-Dimension-3

HCF600-Dimension-4

Downloads

Related Products

TALK TO OUR EXPERT​

  • We will contact you within 12 hours
  • Don’t worry, we hate spam too!
  • 20

    Years of experience

    50+

    Countries & Areas

    500 +

    Customers

    30,000

    ㎡ Manufacturing Factory

    HIITIO logo full 300

    Talk to us now

    What products are you interested in?
    Just in case we can't get back to you in time

    Загрузите наш последний каталог продукции

    ОБЩАЙТЕСЬ С НАШИМ ЭКСПЕРТОМ

    • Мы свяжемся с вами в течение 12 часов
    • Не волнуйтесь, мы тоже ненавидим спам!

    20

    лет опыта

    50+

    Страны и регионы

    500 +

    Клиентов

    30,000

    ㎡ Производственная фабрика

    Download Our Latest Product Catalogue

    Download Our Latest Product Catalogue

    CONTACT US

    Download Our Catalog

    Surge-Protection-Device-SPD-Catalog-Datasheet-PDF