Level 2 Type 2 1000VDC DC Surge Protection Device

  • Type 2 / Class II surge protection for DC power systems
  • Maximum discharge current (Imax): 40 kA (8/20 μs)
  • Response time: ≤ 25 ns
  • Rated voltage options: 600 V, 1000 V, 1200 V, 1500 V DC
  • High-energy MOV technology for stable performance
  • Thermal and visual fault indication (green/red)
  • Optional remote signaling contact (RC)
  • DIN rail mounting, IP20 protection, UL94 V-0 flame-retardant housing
  • Approvals: TUV、CE、RoHS
, ,

Description

The HCDSP2-1000 T2 DC Surge Protector is a high-performance protection device designed to safeguard photovoltaic systems and DC circuits from transient overvoltage events. Certified by TUV, CE, and RoHS, it complies with IEC/EN 61643-31 and GB/T 18802-31 standards, ensuring reliable protection and superior durability. With a discharge current capacity of up to 40 kA (8/20 μs) and ultra-fast 25 ns response time, this SPD effectively suppresses lightning and switching surges in solar inverters, combiner boxes, and energy storage systems.

 

HC-PV serise 600 1000 1200 1500
IEC.GB/T standard
Maximum continuous operating DC voltage(DC+)-PE,(DC-)-PE (DC)-(DC-) 600V 1000V 1200V 1500V
Nominal discharge current(8/20us) 20kA
Total discharge current(8/20 μS} 40KA
Maximum discharge current (8/20μS) 40kA
Voltage protection level (DC+)-PE,(DC-)-PE (DC)- (DC-) ≤2200V ≤4000V ≤4200V ≤5200V
Response time <25ns
Short-circuit current rating 2000A
Number of poles 2,3
Mechanical and environmental characteristics
Operating temperature range -40°F+158F(-40℃ to+70℃)
Allowable working humidity 5%…95%
Atmospheric pressure and altitude 80kPa…106kPa/-500m…2000m
End screw torque 39.9 lbf·in [4.5 Nm]
Maximum intersectional product(max) 2AWG(strand wire)/ 4AWG(flexible wire)35m㎡(strand wire) 25m㎡(flexible wire)
Install 35 mm DINguide rail, According to EN 60715
Protection class IP20(internally installed)
Sheating material Thermoplastics: fire extinguishing class UL94 V0
Thermal protection Yes
Working status/failure indication Green/Red
Communicationcontact(RC) Optional
Ac/DC switching capability AC:250V/0.5A;DC:250V/0.1A;125V/0.2A; 75V/0.5A
Maximum terminal wire cross-sectional area(max) 16AWG(rigid line)/1.5 m㎡(rigid line)

Applications

  • Photovoltaic (PV) inverter input and output protection
  • DC combiner boxes in solar arrays
  • Battery energy storage systems (BESS)
  • DC distribution and control cabinets
  • EV charging stations and renewable microgrids

Dimensions (mm)

Downloads

Certification Files

Related Products

TALK TO OUR EXPERT​

  • We will contact you within 12 hours
  • Don’t worry, we hate spam too!
  • 20

    Years of experience

    50+

    Countries & Areas

    500 +

    Customers

    30,000

    ㎡ Manufacturing Factory

    TALK TO OUR EXPERT​

    Загрузите наш последний каталог продукции

    ОБЩАЙТЕСЬ С НАШИМ ЭКСПЕРТОМ

    • Мы свяжемся с вами в течение 12 часов
    • Не волнуйтесь, мы тоже ненавидим спам!

    20

    лет опыта

    50+

    Страны и регионы

    500 +

    Клиентов

    30,000

    ㎡ Производственная фабрика

    Download Our Latest Product Catalogue

    Download Our Latest Product Catalogue

    CONTACT US

    Download Our Catalog

    Surge-Protection-Device-SPD-Catalog-Datasheet-PDF
    HIITIO logo full 300

    Talk to us now

    What products are you interested in?
    Just in case we can't get back to you in time