Search
Close this search box.

350A 2500Vdc High Voltage DC Contactor

  • Max. Switching Voltage: 2500VDC
  • Rated Current: 350A
  • Main Contact Type: One set of normally open SPST-NO
  • Auxiliary Contact: Optional
  • Auxiliary Contact Type: One set of normally open SPST-NO
  • Coil Rated Voltage: 12VDC/24VDC/48VDC
  • Ambient Operation Temperature: -40°C ~ +85°C
  • Ambient Operation Humidity: 5% ~ 85% RH
  • Approvals/Standard:
    • REACH
    • RoHS
,

Description

MAIN CONTACT DATA
Max. Switching Voltage 2500VDC Rated Current 350A
Contact Arrangement One set of normally open SPST-NO Contact Voltage Drop ≤0.07V(at 350A)
Limiting Short-time Current 400A:10min; 600A:90s; 1000A:100s; 2000A:1s
Electrical Life (Resistive Load) 2000V Model 2500V Model
350A 2000VDC, 500 operations, Only Breaking 350A 2500VDC, 200 operations, Only Breaking
Max. Breaking Current (Resistive Load) 2000A 1000VDC, 1 operation; 1000A 1500VDC, 1 operation
Overload Breaking (Resistive Load) 1000A 900VDC, 100 operations
Short Circuit Current Withstanding 8000A (5ms), No Smoke or Fire
CHARACTERISTIC DATA
Dielectric Strength Between Main Contacts and Coil (Initial) ≥5000VAC (1min) Insulation Resistance Between Main Contacts and Coil (Initial) ≥1000MΩ (2500VDC)
Between Open Main Contacts (Initial) ≥5000VAC (1min) Between Open Main Contacts (Initial) ≥1000MΩ (2500VDC)
Shock Resistance Functional 20g Half-Sine Wave 11ms Vibration Functional Resistance 5.79g (10~2000Hz, Random)
Destructive 50g Half-Sine Wave 6ms
Operate Time Max:50ms Mechanical Life 2*10^5 operations
Release Time Max:30ms Weight Approx 1300g
COIL DATA
Rated Voltage 12VDC 24VDC 48VDC
Pick-up Voltage ≤9VDC ≤18VDC ≤36VDC
Drop-out Voltage ≥1.2VDC ≥2.4VDC ≥4.8VDC
Rated Operating Power Approx 60W (Start); 5.4W (Hold) Approx 60W (Start); 5.4W (Hold) Approx 60W (Start); 5.4W (Hold)

 

MAIN CONTACT DATA
Max. Switching Voltage 2500VDC Rated Current 350A
Contact Arrangement One set of normally open SPST-NO Contact Voltage Drop ≤0.07V(at 350A)
Limiting Short-time Current 400A:10min; 600A:90s; 1000A:100s; 2000A:1s
Electrical Life (Resistive Load) 2000V Model 2500V Model
350A 2000VDC, 500 operations, Only Breaking 350A 2500VDC, 200 operations, Only Breaking
Max. Breaking Current (Resistive Load) 2000A 1000VDC, 1 operation; 1000A 1500VDC, 1 operation
Overload Breaking (Resistive Load) 1000A 900VDC, 100 operations
Short Circuit Current Withstanding 8000A (5ms), No Smoke or Fire
CHARACTERISTIC DATA
Dielectric Strength Between Main Contacts and Coil (Initial) ≥5000VAC (1min) Insulation Resistance Between Main Contacts and Coil (Initial) ≥1000MΩ (2500VDC)
Between Open Main Contacts (Initial) ≥5000VAC (1min) Between Open Main Contacts (Initial) ≥1000MΩ (2500VDC)
Shock Resistance Functional 20g Half-Sine Wave 11ms Vibration Functional Resistance 5.79g (10~2000Hz, Random)
Destructive 50g Half-Sine Wave 6ms
Operate Time Max:50ms Mechanical Life 2*10^5 operations
Release Time Max:30ms Weight Approx 1300g
COIL DATA
Rated Voltage 12VDC 24VDC 48VDC
Pick-up Voltage ≤9VDC ≤18VDC ≤36VDC
Drop-out Voltage ≥1.2VDC ≥2.4VDC ≥4.8VDC
Rated Operating Power Approx 60W (Start); 5.4W (Hold) Approx 60W (Start); 5.4W (Hold) Approx 60W (Start); 5.4W (Hold)
Max. Allowable Voltage 16VDC 32VDC 64VDC

 

MAIN CONTACT DATA
Max. Switching Voltage 2500VDC Rated Current 350A
Contact Arrangement One set of normally open SPST-NO Contact Voltage Drop ≤0.07V (at 350A)
Limiting Short-time Current 400A: 10min; 600A: 90s; 1000A: 100s; 2000A: 1s
Electrical Life (Resistive Load) 2000V Model 2500V Model
350A 2000VDC, 500 operations, Only Breaking 350A 2500VDC, 200 operations, Only Breaking
Max. Breaking Current (Resistive Load) 2000A 1000VDC, 1 operation; 1000A 1500VDC, 1 operation
Overload Breaking (Resistive Load) 1000A 900VDC, 100 operations
Short Circuit Current Withstanding 8000A (5ms), No Smoke or Fire
CHARACTERISTIC DATA
Dielectric Strength Between Main Contacts and Coil (Initial) ≥5000VAC (1min) Insulation Resistance Between Main Contacts and Coil (Initial) ≥1000MΩ (2500VDC)
Between Open Main Contacts (Initial) ≥5000VAC (1min) Between Open Main Contacts (Initial) ≥1000MΩ (2500VDC)
Between Main Contacts and Auxiliary Contact (Initial) ≥5000VAC (1min) Between Main Contacts and Auxiliary Contact (Initial) ≥1000MΩ (2500VDC)
Shock Resistance Functional 20g Half-Sine Wave 11ms Vibration Resistance Functional 5.79g (10~2000Hz, Random)
Destructive 50g Half-Sine Wave 6ms
Operate Time Max: 50ms Mechanical Life 2*10^5 operations
Release Time Max: 30ms Weight Approx 1300g
COIL DATA
Rated Voltage 12VDC 24VDC 48VDC
Pick-up Voltage ≤9VDC ≤18VDC ≤36VDC
Drop-out Voltage ≥1.2VDC ≥2.4VDC ≥4.8VDC
Rated Operating Power Approx 60W (Start); 5.4W (Hold) Approx 60W (Start); 5.4W (Hold) Approx 60W (Start); 5.4W (Hold)
Max. Allowable Voltage 16VDC 32VDC 64VDC
AUXILIARY CONTACT DATA
Auxiliary Contact Arrangement One set of normally open SPST-NO Auxiliary Contact Range 100mA/8VDC~2A/30VDC
Auxiliary Contact Resistance ≤200mΩ (at 100mA)

 

MAIN CONTACT DATA
Max. Switching Voltage 2500VDC Rated Current 350A
Contact Arrangement One set of normally open SPST-NO Contact Voltage Drop ≤0.07V (at 350A)
Limiting Short-time Current 400A: 10min; 600A: 90s; 1000A: 100s; 2000A: 1s
Electrical Life (Resistive Load) 2000V Model 2500V Model
350A 2000VDC, 500 operations, Only Breaking 350A 2500VDC, 200 operations, Only Breaking
Max. Breaking Current (Resistive Load) 2000A 1000VDC, 1 operation; 1000A 1500VDC, 1 operation
Overload Breaking (Resistive Load) 1000A 900VDC, 100 operations
Short Circuit Current Withstanding 8000A (5ms), No Smoke or Fire
CHARACTERISTIC DATA
Dielectric Strength Between Main Contacts and Coil (Initial) ≥5000VAC (1min) Insulation Resistance Between Main Contacts and Coil (Initial) ≥1000MΩ (2500VDC)
Between Open Main Contacts (Initial) ≥5000VAC (1min) Between Open Main Contacts (Initial) ≥1000MΩ (2500VDC)
Between Main Contacts and Auxiliary Contact (Initial) ≥5000VAC (1min) Between Main Contacts and Auxiliary Contact (Initial) ≥1000MΩ (2500VDC)
Shock Resistance Functional 20g Half-Sine Wave 11ms Vibration Resistance Functional 5.79g (10~2000Hz, Random)
Destructive 50g Half-Sine Wave 6ms
Operate Time Max: 50ms Mechanical Life 2*10^5 operations
Release Time Max: 30ms Weight Approx 1300g
COIL DATA
Rated Voltage 12VDC 24VDC 48VDC
Pick-up Voltage ≤9VDC ≤18VDC ≤36VDC
Drop-out Voltage ≥1.2VDC ≥2.4VDC ≥4.8VDC
Rated Operating Power Approx 60W (Start); 5.4W (Hold) Approx 60W (Start); 5.4W (Hold) Approx 60W (Start); 5.4W (Hold)
Max. Allowable Voltage 16VDC 32VDC 64VDC
AUXILIARY CONTACT DATA
Auxiliary Contact Arrangement One set of normally open SPST-NO Auxiliary Contact Range 100mA/8VDC~2A/30VDC
Auxiliary Contact Resistance ≤200mΩ (at 100mA)

Applications

  • Electric vehicles
  • Rail transit
  • Charging system
  • Energy storage system
  • Photovoltaic system
  • Aviation
  • Military

Dimensions (mm)

HCF350-2500 Dimension-1

HCF350-2500 Dimension-2

HCF350-2500 Dimension-3

HCF350-2500 Dimension-4

Related Products

TALK TO OUR EXPERT​

  • We will contact you within 12 hours
  • Don’t worry, we hate spam too!
  • 20

    Years of experience

    50+

    Countries & Areas

    500 +

    Customers

    30,000

    ㎡ Manufacturing Factory

    Загрузите наш последний каталог продукции

    ОБЩАЙТЕСЬ С НАШИМ ЭКСПЕРТОМ

    • Мы свяжемся с вами в течение 12 часов
    • Не волнуйтесь, мы тоже ненавидим спам!

    20

    лет опыта

    50+

    Страны и регионы

    500 +

    Клиентов

    30,000

    ㎡ Производственная фабрика

    Download Our Latest Product Catalogue

    Download Our Latest Product Catalogue

    CONTACT US

    Download Our Catalog

    Surge-Protection-Device-SPD-Catalog-Datasheet-PDF
    HIITIO logo full 300

    Talk to us now

    What products are you interested in?
    Just in case we can't get back to you in time