Search
Close this search box.

100A 1500Vdc High Voltage DC Relay Contactors B

  • Max. Switching Voltage: 1500VDC
  • Rated Current: 100A
  • Main Contact Type: SPST-NO (Single Pole Single Throw – Normally Open)
  • Auxiliary Contact: Optional
  • Auxiliary Contact Type: SPST-NO (Single Pole Single Throw – Normally Open)
  • Coil Rated Voltage: 12VDC/24VDC/48VDC
  • Ambient Operation Temperature: -40°C~+85°C
  • Ambient Operation Humidity: 5%~85%RH
  • Approvals/Standard:
    • REACH
    • RoHS
    • UL 60947-4
    • CCC/CE/CB/S Mark
, , , , , ,

Description

MAIN CONTACT DATA
Max.Switching Voltage 1500VDC Rated Current 100A
Contact Arrangement SPST-NO Contact Voltage Drop ≤0.05V(at 100A)
Limiting Short-time Current 150A:120min; 200A:30min; 400A:60s; 1000A:1s
Electrical Life(Resistive Load) 450V Model 800V Model 1000V Model 1500V Model
100A 450VDC 3000ops 100A 800VDC 1000ops 100A 1000VDC 500ops, Only Breaking 15A 1500VDC 6000ops;30A 1500VDC 11000ops Only Making
Max.Breaking Current(Resistive Load) 1000A 450VDC 1ops
Overload Breaking(Resistive Load) 300A 450VDC 100ops
CHARACTERISTIC DATA
DielectricStrength Between MainContacts And Coil Before Test≥4000VAC(1min) After Test≥2500VAC(1min) InsulationResistance Between MainContacts And Coil Before Test≥1000MΩ(1000VDC) After Test≥50MΩ(1000VDC)
Between Open MainContacts Before Test≥3000VAC(1min) After Test≥2500VAC(1min) Between Open MainContacts Before Test≥1000MΩ(1000VDC) After Test≥50MΩ(1000VDC)
ShockResistance Functional 20g Half-Sine Wave 11ms VibrationResistance Functional 5.79g(10~2000HZ, Random)
Destructive 50g Half-Sine Wave 6ms
Operate Time Max:30ms Mechanical Life 2*105(ops)
Release Time Max:10ms Weight Approx 350g
COIL DATA
Rated Voltage 12VDC 24VDC 48VDC
Pick-up Voltage ≤9VDC ≤18VDC ≤36VDC
Drop-out Voltage ≥1.2VDC ≥2.4VDC ≥4.8VDC
Rated Operating Power Approx 6W Approx 6W Approx 6W
Max.Allowable Voltage 16VDC 32VDC 64VDC

 

MAIN CONTACT DATA
Max.Switching Voltage 1500VDC Rated Current 100A
Contact Arrangement SPST-NO Contact Voltage Drop ≤0.05V(at 100A)
Limiting Short-time Current 150A:120min; 200A:30min; 400A:60s; 1000A:1s
Electrical Life(Resistive Load) 450V Model 800V Model 1000V Model 1500V Model
100A 450VDC 3000 ops 100A 800VDC 1000 ops 100A 1000VDC 500 ops, Only Breaking 15A 1500VDC 6000 ops; 30A 1500VDC 11000 ops Only Making
Max.Breaking Current(Resistive Load) 1000A 450VDC 1 ops
Overload Breaking(Resistive Load) 300A 450VDC 100 ops
CHARACTERISTIC DATA
Dielectric Strength Between Main Contacts And Coil Before Test ≥4000VAC(1min) After Test ≥2500VAC(1min) Insulation Resistance Between Main Contacts And Coil Before Test ≥1000MΩ(1000VDC) After Test ≥50MΩ(1000VDC)
Between Open Main Contacts Before Test ≥3000VAC(1min) After Test ≥2500VAC(1min) Between Open Main Contacts Before Test ≥1000MΩ(1000VDC) After Test ≥50MΩ(1000VDC)
Between Main Contacts And Auxiliary Contacts Before Test ≥3000VAC(1min) After Test ≥2500VAC(1min) Between Main Contacts And Auxiliary Contacts Before Test ≥1000MΩ(1000VDC) After Test ≥50MΩ(1000VDC)
Shock Resistance Functional 20g Half-Sine Wave 11ms Vibration Resistance Functional 5.79g (10~2000HZ, Random)
Destructive 50g Half-Sine Wave 6ms
Operate Time Max:30ms Mechanical Life 2*10^5 ops
Release Time Max:10ms Weight Approx 350g
COIL DATA
Rated Voltage 12VDC 24VDC 48VDC
Pick-up Voltage ≤9VDC ≤18VDC ≤36VDC
Drop-out Voltage ≥1.2VDC ≥2.4VDC ≥4.8VDC
Rated Operating Power Approx 6W Approx 6W Approx 6W
Max.Allowable Voltage 16VDC 32VDC 64VDC
AUXILIARY CONTACT DATA
Auxiliary Contact Arrangement SPST-NO Auxiliary Contact Range 100mA/8VDC~2A/30VDC
Auxiliary Contact Resistance ≤200mΩ (at 100mA)

Applications

  • Electric vehicles
  • Rail transit
  • Charging system
  • Energy storage system
  • Photovoltaic system
  • Aviation
  • Military

Dimensions (mm)

HCF100B Dimension-1

HCF100B Dimension-1

Downloads

Related Products

TALK TO OUR EXPERT​

  • We will contact you within 12 hours
  • Don’t worry, we hate spam too!
  • 20

    Years of experience

    50+

    Countries & Areas

    500 +

    Customers

    30,000

    ㎡ Manufacturing Factory

    Загрузите наш последний каталог продукции

    ОБЩАЙТЕСЬ С НАШИМ ЭКСПЕРТОМ

    • Мы свяжемся с вами в течение 12 часов
    • Не волнуйтесь, мы тоже ненавидим спам!

    20

    лет опыта

    50+

    Страны и регионы

    500 +

    Клиентов

    30,000

    ㎡ Производственная фабрика

    Download Our Latest Product Catalogue

    Download Our Latest Product Catalogue

    CONTACT US

    Download Our Catalog

    Surge-Protection-Device-SPD-Catalog-Datasheet-PDF
    HIITIO logo full 300

    Talk to us now

    What products are you interested in?
    Just in case we can't get back to you in time